AI-assisted disk diffusion reading
Read an antibiotic plate from a photo
AST Smart finds each antibiotic disk, measures the clear zone and interprets it — right on your device.
How it works
1Photograph the platePhone, tablet or a saved image
2Choose the organismCLSI or EUCAST breakpoints
SIR3Get S / I / RFor every antibiotic disk
Photos never leave your device
CLSI 2026 · EUCAST 2026
For a clear reading
Dark, matte background
Camera parallel to the plate
No glare or reflections
Which organism was tested?
We'll read the plate while you choose.
Breakpoints
Results
ⓘ No plate rim was found — check that the whole plate is in the photo.
Research prototype — not for clinical use. Results must be confirmed by qualified staff.
Expert mode — all settings, annotation, exports and diagnostics.
Expert workspace
AST Smart · v0.6.0-beta.3
Starting…
Research prototype — not for clinical use.
Images never leave this device: the AI model runs in your browser.
Zone diameters are measured on the image (ROI radial edge, read at the point of complete inhibition by default) and have not been validated against manual readings. S/I/R (when an organism and antibiotic are chosen) comes from the selected breakpoint table and must be confirmed by qualified staff.
Preparing the on-device AI model…
About 25 MB on the first visit, then loaded from this device. You can pick a photo now; analysis starts as soon as the model is ready.
1 Image
or drop an image here
Try a sample:
Tips: place the plate on a dark, non-reflective background, hold the phone parallel to the plate, and avoid glare.
2 Organism & interpretation
Choose the organism, then the antibiotic of each disk in the result table. S/I/R uses the zone diameter rounded to the nearest whole millimetre. Tables you load stay on this device (browser storage) and are never uploaded. Research use only — confirm against the official tables and your laboratory's procedures.
3 Settings
Plate
The plate rim is found automatically from the image edges, guided by the detected disks. Settings re-filter the last result instantly; only the second-pass option runs the model again.
Disk codes
Two readers (a CNN and PP-OCR) read the code printed on each disk after the zones are measured; the models (7.6 MB) download on first use and are then cached. auto = both readers agree, used for S/I/R · review = suggestion, used only after you accept it · unresolved = nothing filled in · your choice always wins. Held-out test (15 plates, 94 disks): every disk = 90 auto, 0 wrong, 4 review; “only when unsure” = 91 auto, 0 wrong, 3 review, OCR on 22 of 94 disks — but it can auto-fill a disk the CNN reads confidently wrong (marker-pen dots; 1 such disk on the development plates). AZM, CIP, OX and P have too few training disks for an accuracy estimate. The lab panel constraint never forces a code: disks outside the panel go to review.
* Experimental. ROI radial: each disk gets its own region; the clear-to-growth edge is located on up to 72 sectors around the disk (sectors pointing at neighbouring disks or the rim are skipped) and the median radius is reported. The edge is read at the point of complete inhibition (EUCAST reading guide: first visible growth outward from the disk; haze, fuzzy rims and swarming film are not included). If a fuzzy or double edge is found, the outer edge is drawn as a thin dashed ring and can be chosen per disk under “Edge read at” (the guide reads the outer zone only for Proteus swarming and Enterobacterales + ampicillin). Scale = median disk diameter ÷ nominal disk diameter. A “?” / dashed circle means low confidence — please check. “No zone detected” means the detector found no zone around that disk (reported as the disk diameter in exports), not a measured 0 mm.
Report details (laboratory, sample ID, reader)
Laboratory and reader are remembered on this device. Sample ID and comments are cleared for each new photo.
Before you start
This is a research prototype, not a medical device.